DFG Light Commercial Gas/Electric Packaged Unit for Energy-Efficient Heating and Cooling

If you're looking for a reliable and efficient heating and cooling solution for your commercial space, the DFG light commercial gas/electric packaged unit is an excellent option. This self-contained unit provides 14 SEER performance, making it suitable for ground-level or rooftop installations as well as horizontal or downflow applications. Its heavy-gauge, galvanized steel cabinet is designed to withstand all weather conditions and time, thanks to a UV-resistant powder-paint finish.

Key Features of the DFG Light Commercial Gas/Electric Packaged Unit

  • High-efficiency scroll compressor: This compressor delivers reliable and efficient performance for your heating and cooling needs.
  • Copper tube/aluminum fin coils: These coils are designed for maximum heat transfer and durability, ensuring long-lasting performance.
  • High and low pressure switches: These switches protect the unit from damage due to extreme pressure levels, ensuring safety and reliability.
  • High-capacity, steel-cased filter drier: This drier removes moisture and contaminants from the refrigerant, ensuring long-lasting performance and high-quality indoor air.
  • 24 volt terminal strip: This strip simplifies the wiring process and ensures proper voltage delivery, making installation easier.
  • Convertible airflow orientation: This feature allows for flexible installation and optimal performance in different applications, making it a versatile solution for a variety of commercial spaces.
  • Built-in filter rack with standard 2" filters: This rack makes filter replacement easy and ensures clean indoor air quality, promoting a healthy and comfortable environment for occupants.
More Information
Daikin 5 Ton 140,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit | 208/230V 1 Phase - R410A - Single Stage
FeatureSpec
SKUDFG0601DH00001S
Refrigerant ChargePre-charged
Weight (in lbs)645
Brand/ManufacturerDaikin
ReplacesDBG0601DH00001S, DTG0601401DXXX
UPC686797027118
Cooling BTU58,000 BTU
Heating BTU138,000 BTU
Drive TypeDirect
Maximum CFM1800
Decibel Level (dBA)78 decibels
RefrigerantR410A
SEER1 (Efficiency)14
SEER2 (Efficiency)13.4
EER11.6
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208 / 230 V. 1 Phase 60 Hz
PhaseSingle Phase
Max Breaker Size60 amps
Min. Breaker Size41.3 amps
Tonnage5 Ton
Burner StagesModulating
Height38.8"
Width73.9"
Depth48.1"
Warranty5 Years with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety Information
This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.

PROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 5 Ton 140,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit | 208/230V 1 Phase - R410A - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
Can a Commercial Rooftop Unit be installed on the ground instead of the roof?
Yes. Some commercial packaged rooftop units can be installed at ground level when the equipment is designed for horizontal airflow rather than vertical rooftop discharge. These horizontal-flow units require adequate space, a stable mounting surface, proper ductwork connections, and sufficient clearance for airflow and servicing. Always verify the manufacturer's installation requirements and local building codes before selecting a ground-level installation.
Do Commercial Rooftop Units require professional installation?
Yes. Commercial rooftop units should be installed by qualified HVAC professionals to ensure proper equipment placement, electrical connections, ductwork compatibility, refrigerant handling, and system performance. Professional installation helps ensure the unit operates safely and efficiently while meeting applicable building codes, manufacturer requirements, and local regulations.
Did you find what you were looking for?